Fire Rated Expansion Joint Systems
Fire-resistant joint systems that allow safe movement between building sections.


Professional Fire Rated Expansion Joint Work-
Hypery International Ltd. provides certified fire-rated expansion joint sealing systems tailored for critical infrastructure projects in Bangladesh. We work with globally recognized manufacturers like Hilti, STI Firestop, 3M, RectorSeal etc. and others to supply and install UL-classified and FM-approved firestop solutions. Our services are implemented in line with the International Building Code (IBC) and follow UL 2079 and ASTM E1966 testing standards.
We have successfully executed fire-rated joint systems across multiple sectors, including:
- Export-oriented Textile & Garment factories.
- Government mega-projects (e.g., Metro Rail, Airport Terminal).
- Private commercial buildings and high-rises.
Our solutions ensure compliance with RSC Bangladesh, Elevated, and Nirapon 2.0 standards—ensuring acceptance in third-party safety audits.

Work Process & Methodology
We follow a structured, international standard-driven workflow for all fire-rated expansion joint installations:
1. Project Assessment & Site Visit
Our team of certified engineers performs a comprehensive site inspection. We assess structural movement requirements, joint widths, fire rating expectations, and identify the correct UL system(s) applicable.
2. Free Consultancy & Submittal Preparation
We offer free technical consultancy and develop a complete submittal package, including:
- System drawings & specifications
- Product data sheets
- UL system references
- Installation methodology
- Safety documentation
This is submitted to the client or auditor (e.g., RSC, Elevated, Nirapon) for review and approval.
3. UL-Compliant Installation
Our installations are carried out by trained teams, certified by manufacturers such as Hilti, STI, 3M, etc. Our team includes supervisors with credentials from BUET, DUET, or international fire engineering institutes.
4. Quality Assurance & Reporting
Upon completion, we submit a detailed Final Completion Report, which includes:
- Pictorial documentation (before/during/after)
- Product batch certificates
- UL System ID reference
- Installer and supervisor logs
- QA checklist as per RSC/Elevated requirements
We have successfully executed joint firestopping systems on several of Bangladesh’s flagship infrastructure projects. Our systems are rigorously engineered to accommodate movement gaps up to 6 inches, with fire resistance ratings of 2, 3, and 4 hours, verified through UL 2079, ASTM E1966, and relevant NFPA and BNBC standards.
Project Execution Gallery - Factory Installation
– Explore our on-site fire safety works in real projects.
Our Expert Engineering Panel
We work with highly qualified engineers from BUET, DUET, RUET, and other reputed institutions. Many of our team members are NFPA-certified and have completed specialized fire safety training from abroad. Their combined expertise ensures every project meets both local and international fire safety standards.